Floor Plan
(b)

a floor plan of each storey and flat roof of the building containing or showing-

(i) clear statement indicating the purpose for which every part of the storey is to be used, and the provision in accordance with the

(ii) requirement of the Code of fire practices of means of escape in case of fire.

(ii) the type of materials to be used for the walls, super-structure and floor slabs of the building or in the building works and the maximum permissible live load that such floor slabs are designed to carry;

(iii) dimensions in figures dimensions of the building and all rooms, compartments, corridors, staircases, verandas and roof terraces and the thickness of the walls and columns thereof;

(iv) dimensions in figures of the clear areas of every air-well, back-yard, court-yard and open space in and around the building and the distances from the external walls of the building to the centre line and side of every street, road reserve, and drainage reserve within the lot or adjoining thereto;

(v) dimensions in figures of space between all walls, piers and stanchions;

(vi) the positions of all sanitary appliances, vent pipes and floor traps and their connections to drain lines;

(vii) all the lines of the surface drainage in or around the building with arrows indicating the direction of flow of water and the outlet drains into which the water discharges and the sizes of these outlet drains;

(viii) the means of escape from fire and the fire prevention measures taken in respect of the building including the provisions of fire extinguishing equipment and installations therein; and

(ix) clear statements indicating every part of each storey of the building that is to be air-conditioned, mechanically ventilated or pressurised and, where such part is to be air-conditioned, whether the air-conditioning shall be by means of a centralised system or package unit and wherever possible the position or positions of the air-conditioning plant or unit shall be indicated on the floor plan;


Sections
(c)

cross, longitudinal and other sectional drawings of the building clearly delineating the disposition of the adjoining ground and showing -

(i) the types of materials used and the thickness of all walls, floors, roofs, ceilings, foundations, beams, roof slabs, drains, and aprons, and other related parts of the building;

(ii) the existing ground level or levels and any proposed new ground level or levels if the building site is to be raised or lowered with clear statements as to how the new ground level or levels might affect the stability of all adjoining land or buildings and what steps are being taken to safeguard the same;

(iii) dimensions in figures of the distances from any existing or required retaining wall or slops of the site, which exceeds one and a half metres in height, to the proposed building ,the lot boundaries thereof and any existing building on adjoining land that is within ten metres of the retaining wall or slope and is nearest thereto; and

(iv) dimensions in figures of the door, window or ventilation openings, the height of every storey, the ceiling height and the ground floor level or levels and footway level or levels of the Building in relation to the existing ground and street level or levels thereof, and the clear distances between the lot boundary and the external walls of the building;