| Floor
Plan | |
| (b) |
a floor plan of each storey
and flat roof of the building containing or showing-
| | |
(i) clear statement indicating
the purpose for which every part of the storey is to be used, and the provision
in accordance with the
(ii) requirement of the Code of fire practices
of means of escape in case of fire.
(ii) the type of materials to be used
for the walls, super-structure and floor slabs of the building or in the building
works and the maximum permissible live load that such floor slabs are designed
to carry;
(iii) dimensions in figures dimensions of the building and all
rooms, compartments, corridors, staircases, verandas and roof terraces and the
thickness of the walls and columns thereof;
(iv) dimensions in figures
of the clear areas of every air-well, back-yard, court-yard and open space in
and around the building and the distances from the external walls of the building
to the centre line and side of every street, road reserve, and drainage reserve
within the lot or adjoining thereto;
(v) dimensions in figures of space
between all walls, piers and stanchions;
(vi) the positions of all sanitary
appliances, vent pipes and floor traps and their connections to drain lines;
(vii)
all the lines of the surface drainage in or around the building with arrows indicating
the direction of flow of water and the outlet drains into which the water discharges
and the sizes of these outlet drains;
(viii) the means of escape from
fire and the fire prevention measures taken in respect of the building including
the provisions of fire extinguishing equipment and installations therein; and
(ix) clear statements indicating every part of each storey of the building
that is to be air-conditioned, mechanically ventilated or pressurised and, where
such part is to be air-conditioned, whether the air-conditioning shall be by means
of a centralised system or package unit and wherever possible the position or
positions of the air-conditioning plant or unit shall be indicated on the floor
plan; | Sections | | (c)
| cross,
longitudinal and other sectional drawings of the building clearly delineating
the disposition of the adjoining ground and showing -
| | |
(i) the types of materials
used and the thickness of all walls, floors, roofs, ceilings, foundations, beams,
roof slabs, drains, and aprons, and other related parts of the building;
(ii) the existing ground level or levels and any proposed new ground level or
levels if the building site is to be raised or lowered with clear statements as
to how the new ground level or levels might affect the stability of all adjoining
land or buildings and what steps are being taken to safeguard the same;
(iii)
dimensions in figures of the distances from any existing or required retaining
wall or slops of the site, which exceeds one and a half metres in height, to the
proposed building ,the lot boundaries thereof and any existing building on adjoining
land that is within ten metres of the retaining wall or slope and is nearest thereto;
and
(iv) dimensions in figures of the door, window or ventilation openings,
the height of every storey, the ceiling height and the ground floor level or levels
and footway level or levels of the Building in relation to the existing ground
and street level or levels thereof, and the clear distances between the lot boundary
and the external walls of the building;
|
| | |
|
 |
|