| Elevations |
| (d) |
front, rear and side elevations
of the building showing- |
| |
(i) all the external walls,
external columns, parapet walls and doors, windows or ventilation openings, canopies
and balconies and the roof of the building with dimensions in figures and the
types of materials to be used in the construction of the external walls, external
columns, parapet walls, openings canopies, balconies and roof where required by
the Authority;
(ii) part elevation or elevations of every existing adjoining
building showing its height, floor levels, external walls, doors, windows, roof
and other external and visible features, with indications of the types of materials
used in the construction thereof; in such special locations where the Authority
has to give detailed guidelines; and
(iii) the levels of every adjoining
footway, verandah way, street and ground of the building and the levels of all
proposed counterparts of the footway, verandah way, street and ground; and |
Other
details |
|
particulars or information
relating to the building or building works as the Authority may require. |
Colouring
of plans specifications of material used in building works |
| 11. | (1) |
Every plan submitted under
the Law shall be drawn in black ink or produced in print and all extension to
the existing building works shown on the plans shall be coloured red. Each unit
should be given a different colour.
|
| (2) |
All parts of an existing
Building that are to be removed shall be shown in dotted lines on the plans
|
| (3) |
If so required by the Authority
a plan submitted under the Law shall be accompanied by specifications of all materials
proposed to be used in the building works of which the plans are submitted.
|
Installation
or extension or alteration of any air conditioning mechanical ventilation or fire
protection systen |
| 12. | Where
any air- conditioning, mechanical ventilation or fire protection system is to
be installed in a building or part thereof or any such system therein is to be
extended altered, layout and detailed plans of the installation or the extension
of alteration as the case may be, shall, before the installation,extension or
alteration is carried out, be submitted to the Authority for approval along with
a certificate from qualified person, not withstanding plans of the buildings in
which the system is to be installed extended or altered have been provided under
regulation 7. |
Structural
details and calculation |
| 13 | (1) |
The detailed structural
plans of any building works other than those indicated in Regulation 3 (1) c (i)
& (ii) shall be submitted to the Authority together with a copy of the design
calculation before the building works are carried out or resumed.
|
| (2) |
The detailed structural
plans and design calculations shall be prepared in accordance with the provision
of the Law these regulations, and any other written law relating to building construction
and signed by the qualified person who prepared the detailed structural plans
and design calculations, and shall show -
|
| |
(a) clearly the superimposed
load for which each floor system or part thereof has been designed;
(b)
the results of any soil test carried out, the calculations for any determination
of soil bearing capacity and complete boring investigations and details of the
soil;
(c)the type or types of foundation to be used; and
(d) the
type of piles, method of pile driving and type of machinery to be employed in
piling, if the same is required.
|
| (3) |
A certificate from a qualified
person shall be submitted. |