Advice | LandSales | Houses-for-sale | Apartments | Rentals | InteriorDecor | Landscaping | Contractors | Mortgage | Security | Tiles | Roofing | CAD&3D | Advice | Consultants | Government


 
 

Elevations
(d)

front, rear and side elevations of the building showing-

(i) all the external walls, external columns, parapet walls and doors, windows or ventilation openings, canopies and balconies and the roof of the building with dimensions in figures and the types of materials to be used in the construction of the external walls, external columns, parapet walls, openings canopies, balconies and roof where required by the Authority;

(ii) part elevation or elevations of every existing adjoining building showing its height, floor levels, external walls, doors, windows, roof and other external and visible features, with indications of the types of materials used in the construction thereof; in such special locations where the Authority has to give detailed guidelines; and

(iii) the levels of every adjoining footway, verandah way, street and ground of the building and the levels of all proposed counterparts of the footway, verandah way, street and ground; and


Other details

particulars or information relating to the building or building works as the Authority may require.


Colouring of plans specifications of material used in building works
11.(1)

Every plan submitted under the Law shall be drawn in black ink or produced in print and all extension to the existing building works shown on the plans shall be coloured red. Each unit should be given a different colour.

(2)

All parts of an existing Building that are to be removed shall be shown in dotted lines on the plans

(3)

If so required by the Authority a plan submitted under the Law shall be accompanied by specifications of all materials proposed to be used in the building works of which the plans are submitted.


Installation or extension or alteration of any air conditioning mechanical ventilation or fire protection systen
12.Where any air- conditioning, mechanical ventilation or fire protection system is to be installed in a building or part thereof or any such system therein is to be extended altered, layout and detailed plans of the installation or the extension of alteration as the case may be, shall, before the installation,extension or alteration is carried out, be submitted to the Authority for approval along with a certificate from qualified person, not withstanding plans of the buildings in which the system is to be installed extended or altered have been provided under regulation 7.

Structural details and calculation
13(1)

The detailed structural plans of any building works other than those indicated in Regulation 3 (1) c (i) & (ii) shall be submitted to the Authority together with a copy of the design calculation before the building works are carried out or resumed.

(2)

The detailed structural plans and design calculations shall be prepared in accordance with the provision of the Law these regulations, and any other written law relating to building construction and signed by the qualified person who prepared the detailed structural plans and design calculations, and shall show -

(a) clearly the superimposed load for which each floor system or part thereof has been designed;

(b) the results of any soil test carried out, the calculations for any determination of soil bearing capacity and complete boring investigations and details of the soil;

(c)the type or types of foundation to be used; and

(d) the type of piles, method of pile driving and type of machinery to be employed in piling, if the same is required.

(3)

A certificate from a qualified person shall be submitted.