Height
of rooms in residential buildings |
|
50 |
(1) |
The height of rooms in
residential buildings shall be -
|
|
|
|
(a) for living rooms and bedrooms not less than 2.8 m ;
(b) for kitchens
not less than 2.8 m; and
(c) for bathrooms, lavatories, water-closets,
porches, balconies, terraces and garages not less than 2.2 m. |
|
Shops
|
|
| (2) |
The height of ground floor
rooms in a shop shall be not less than 3.0 m and the height of upper floor rooms
shall be not less than 2.8 m. |
|
Schools
|
|
| (3) |
The height of classrooms
in a school shall be not less than 35m. |
|
Hospitals
|
|
| (4) |
The height of rooms used
for the accommodation of patients in a hospital shall be not less than 3.5 m.
Factories |
| Factories
|
|
| (5) |
The height of rooms in
a factory in which any person works shall be not less than 3.0 m. |
|
Resort
buildings
|
|
| (6)
|
(a) The height of rooms in a place of public resort shall be not less than 3.0
m. Where a balcony is provided in a place of public resort the height between
the level of the topmost tier of the balcony and the ceiling over such topmost
tier, and the height between the floor immediately under the balcony and the underside
of the balcony, shall be not less than 3.0 m in each case. (b) In a place of
public resort the provisions of paragraph (7) shall apply to water -closets, lavatories,
cloak rooms,, kitchens, corridors and rooms to which the public do not have access. |
|
Other
buildings
|
|
| (7)
| In
a building other than any of those specified in a paragraphs (1) to (6) the height
of the rooms on the ground floor shall be not less than 3.0 m and on upper floors
not less than 2.8 m except that any part of a ground floor or upper floor may
be not less than -
(a) 2.6 m if such part is left open and used as a covered
garden; or
(b) 2.40 m if used for car parking purposes. |
|
Basement
|
|
| (8)
| In
a basement storey the height of any part thereof or of any room not otherwise
specified in paragraphs (1) to (7) shall not be less than -
(a) 2.8 m
if used as shops, offices, business premises, plant rooms or the like;
(b)
2.60 m if used for storage purposes; or
(c) 2.4 m if used for car parking
purposes. |
| Clear
height of car parking areas
|
|
| (9)
| Notwithstanding
the provisions of paragraph (7) and (8), in those parts of a building used or
intended to be used principally for car - parking purposes, the minimum clear
height at any part, including the underside of ceiling beams, ducts, sprinkler
heads, service pipes, lightings, fixtures and the like, shall be not less than
2.2 m. |
| Minimum
height of covered footways
|
|
|
| 51.
The height of any covered footway constructed pursuant to regulation 50 shall
be not less than 3.0 m below which height only the following items may project
if the underside of such items be not less than 2.5 m from the footway paving:- (a)
beams;
(b) stairways and landings;
(c) screens; and
(d)
signboards and advertisements. |